This article provides an overview of the power levels for different configurations of the WIT 4K-15K inverters in combination with the AXE 5.0 LV battery. We also offer a brief recommendation for the correct current protection per configuration.
This way, you know exactly what to pay attention to during installation and avoid surprises in the distribution board.
Current protection:
| Inverter: | maximum AC output of the inverter | Minimum current protection | Minimum main connection |
| WIT 4k-HU | 6.4A | 16A | 25A |
| WIT 5k-HU | 7.9A | 16A | 25A |
| WIT 6k-HU | 9.6A | 16A | 25A |
| WIT 8k-HU | 12.8A | 16A | 25A |
| WIT 10k-HU | 15.9A | 20A | 25A |
| WIT 12k-HU | 19.1A | 25A | 35A |
| WIT 15k-HU | 23.9A | 30A | 40A |
Output power:
| Nominal charge/discharge: | ||||||
| Inverter: | 5 kWh | 10 kWh | 15 to 50 kWh | 55 kWh | 60 kWh | 65 to 100 kWh |
| WIT 4k-HU | 2.5/3.1 kW | 4 kW | 4 kW | 4 kW | 4 kW | 4 kW |
| WIT 5k-HU | 2.5/3.1 kW | 5 kW | 5 kW | 5 kW | 5 kW | 5 kW |
| WIT 6k-HU | 2.5/3.1 kW | 5.1/6.1 kW | 6 kW | 6 kW | 6 kW | 6 kW |
| WIT 8k-HU | 2.5/3.1 kW | 5.1/6.1 kW | 8 kW | 8 kW | 8 kW | 8 kW |
| WIT 10k-HU | 2.5/3.1 kW | 5.1/6.1 kW | 8.1 kW | 10 kW | 10 kW | 10 kW |
| WIT 12k-HU | 2.5/3.1 kW | 5.1/6.1 kW | 8.1 kW | 10.6/11.2 kW | 12 kW | 12 kW |
| WIT 15k-HU | 2.5/3.1 kW | 5.1/6.1 kW | 8.1 kW | 10.6/11.2 kW | 13.2/14.2 kW | 15 kW |